SPARQL Result for Associations (Non-Compositions)

type_of_member_end_2 upper_of_member_end_2 name_of_member_end_1 type_of_member_end_1 upper_of_member_end_1 description proteus_association_type_of_member_end_1 proteus_association_type_of_member_end_2
ActuatingFunction 1 ActuatingLocation PipingNetworkSegment 1 The actuating location of the ActuatingFunction. is located in is the location of
ActuatingFunction * Systems ActuatingSystem 1 The ActuatingSystem that implements the ActuatingFunction. is fulfilled by fulfills
AgitatorRotor * Chamber Chamber 1 The Chamber in which the AgitatorRotor is located, if applicable. The Chamber must be a component of the same object as the AgitatorRotor. is located in is the location of
AreaIsa95LocatedStructure * AreaIsa95 AreaIsa95 1 The AreaIsa95 in which the AreaIsa95LocatedStructure is located. is located in is the location of
Displacer * Chamber Chamber 1 The Chamber in which the Displacer is located, if applicable. The Chamber must be a component of the same object as the Displacer. is located in is the location of
FilterUnit * Chamber Chamber 1 The Chamber in which the FilterUnit is located, if applicable. The Chamber must be a component of the same object as the FilterUnit. is located in is the location of
HeatExchanger 1 Agitator Agitator 1 The Agitator of the HeatExchanger, if applicable. is the location of is located in
HeatExchangerRotor * Chamber Chamber 1 The Chamber in which the HeatExchangerRotor is located, if applicable. The Chamber must be a component of the same object as the HeatExchangerRotor. is located in is the location of
Impeller * Chamber Chamber 1 The Chamber in which the Impeller is located, if applicable. The Chamber must be a component of the same object as the Impeller. is located in is the location of
IndustrialComplexIso10209-2012 * ParentStructure IndustrialComplexIso10209-2012ParentStructure 1 A superordinate structure of which the IndustrialComplexIso10209-2012 is a part. is a part of is a collection including
InlinePrimaryElementReference 1 InlinePrimaryElement InlinePrimaryElement 1 The InlinePrimaryElement referenced by the InlinePrimaryElementReference. refers to is referenced by
InstrumentationLoopFunction 1 ProcessInstrumentationFunctions ProcessInstrumentationFunction * The ProcessInstrumentationFunctions that constitute this InstrumentationLoopFunction. is a collection including is a part of
MixingElementAssembly * Chamber Chamber 1 The Chamber in which the MixingElementAssembly is located, if applicable. The Chamber must be a component of the same object as the MixingElementAssembly. is located in is the location of
Nozzle * Chamber Chamber 1 The Chamber at which the Nozzle is located, if applicable. The Chamber must be a component of the same object as the Nozzle. is located in is the location of
PipingConnection 1 SourceItem PipingSourceItem 1 The PipingSourceItem at which the PipingConnection starts.    
PipingConnection 1 SourceNode PipingNode 1 The PipingNode at which the PipingConnection starts. The SourceNode must belong to the SourceItem.    
PipingConnection 1 TargetItem PipingTargetItem 1 The PipingTargetItem at which the PipingConnection starts.    
PipingConnection 1 TargetNode PipingNode 1 The PipingNode at which the PipingConnection ends. The TargetNode must belong to the TargetItem.    
PipingNetworkSegment 1 SourceItem PipingSourceItem 1 The item at which the PipingNetworkSegment starts.    
PipingNetworkSegment 1 SourceNode PipingNode 1 The Node at which the PipingNetworkSegment starts.    
PipingNetworkSegment 1 TargetItem PipingTargetItem 1 The item at which the PipingNetworkSegment ends.    
PipingNetworkSegment 1 TargetNode PipingNode 1 The Node at which the PipingNetworkSegment ends.    
PlantSectionIso10209-2012 * ParentStructure PlantSectionIso10209-2012ParentStructure 1 A superordinate structure of which the PlantSectionIso10209-2012 is a part. is a part of is a collection including
PlantSystemLocatedStructure * PlantSystem PlantSystem 1 The PlantSystem in which the PlantSystemLocatedStructure is located. is located in is the location of
PlantTrainLocatedStructure * PlantTrain PlantTrain 1 The PlantTrain in which the PlantTrainLocatedStructure is located. is located in is the location of
ProcessPlant * ParentStructure ProcessPlantParentStructure 1 A superordinate structure of which the ProcessPlant is a part. is a part of is a collection including
ProcessSignalGeneratingFunction * SensingLocation SensingLocation 1 The sensing location of the ProcessSignalGeneratingFunction. is located in is the location of
ProcessSignalGeneratingFunction * Systems ProcessSignalGeneratingSystem 1 The ProcessSignalGeneratingSystem that implements the ProcessSignalGeneratingFunction. is fulfilled by fulfills
ShutOffValveReference 1 Valve ShutOffValve 1 The actual valve referenced by the ShutOffValveReference. refers to is referenced by
SignalConveyingFunction * Source SignalConveyingFunctionSource 1 The source of the signal conveyed by this SignalConveyingFunction. has logical start is logical start of
SignalConveyingFunction * Target SignalConveyingFunctionTarget 1 The target of the signal conveyed by this SignalConveyingFunction. has logical end is logical end of
SiteIsa95 * ParentStructure Isa95Enterprise 1 A superordinate structure of which the SiteIsa95 is a part. is a part of is a collection including
TechnicalItem * ParentStructure TechnicalItemParentStructure 1 A superordinate structure of which the TechnicalItem is a part. is a part of is a collection including
TubeBundle * Chamber Chamber 1 The Chamber in which the TubeBundle is located, if applicable. The Chamber must be a component of the same object as the TubeBundle. is located in is the location of
Vessel 1 Agitator Agitator 1 The Agitator of the Vessel, if applicable. is the location of is located in
Vessel 1 ColumnSections TaggedColumnSection * The column sections of the Vessel, if applicable. is the location of is located in